Surge generator(from site:sz3ctest)

来源:网络  作者:网络转载   2019-09-29 阅读:859
HOST
Automatic lightning surge generator SG-5006G (desktop) equipment used to assess the power cord and stood in line to connect the internal switch to switch from the natural world and lightning caused by the high-energy transient interference performance to provide a common basis. Performance fully meet the IEC61000-4-5 and GB/T17626.5 standards.

According to
IEC: 61000-4-5.
Model Number: SG-5006G


Technical characteristics:
● large-screen LCD display, built-in computer control, human-computer dialogue, easy to operate
● program-controlled high-voltage power supply, voltage stability, high accuracy current and voltage breakdown shows
● main switch of imports of electronic switch used to ensure the stability of the wave, comparable strong, long life● positive or negative automatic switch, the test may turn positive and negative polarity switch
● surge interfere with the control software on a trial basis, people need to operate
● surge into the phase angle 0-360 ° set free
● built-in IEC61000-4-5 standard four-Test level
● built-in current and voltage probes can be connected directly to oscilloscope waveform observation (optional)● RS-232 communication interface, remote control, monitoring and control system software can match.

Output voltage 0.25~6kV±5%
Output polarity positive or negative, positive and negative turn of the
Output voltage wave 1.2/50us ± 30%
Output current wave 8/20us ± 30%
output impedance
Output short-circuit current 0.125~3kA
Surge into the phase 0 ~ 360 ° set free
Manner triggers synchronous / asynchronous set free
  IEC standard built-in level four standard test rating
Coupling inligent decoupling network (matching) SGN-20G (automatic superposition of three-phase five-line, 20A) SGN-5010G (automatic superposition of single-phase, 10A)
power AC220V ± 10%, 50/60Hz
Size (mm) 460*520*310

 NETWORK


Smart lightning surge coupling / decoupling network of SGN-5010G single-phase network and SGN-20G is a three-phase network. Is devoted to automatic lightning surge generator SG-5006G (desktop) portfolio. Network performance in line with the IEC61000-4-5 and GB/T17626.5 standards.

According to

IEC61000-4-5.
Model Number: SGN-5010G SGN-20G
Coupling method: capacitor coupling
Coupling capacitor: 9μF(common mode test)18μF(normal mode test)
Decoupling inductor: 1.5mH
Specifications 
Item SGN-5010G SGN-20G
Surge waveform 1.2/50μs voltage waveform, 8/20μs current waveform
Max. input voltage 6.6kV
Max. input current 3.3kA
Coupling mode choice      Auto  operation
Power capacity of EUT Single phase, 3 wire, 220V, 10A 380V,20A Three phase, 5 wire, 380V, 20A
Power AC 220V  50/60Hz
Operating temp. 15℃-35℃
Weight 28kg 38kg
  Dimensions(D×W×H)mm 460*520*240 460*520*310
交流咨询:   在线:
 欢迎交流电磁兼容EMC&高压测试(冲击电压、冲击电流)进入:了解更多其他配置方案及知识电磁兼容配置方案一、电磁兼容知识大汇总二、静电放电抗干扰试验系统【IEC61000-4-2 三、射频磁场辐射抗绕度试验【IEC61000-4-3 四、电快速瞬变脉冲群的抗干扰度试验【IEC61000-4-4 五、雷击浪涌抗干扰度试验【IEC61000-4-5 六、射频传导抗扰度试验【IEC61000-4-6 七、工频磁场抗扰度试验【IEC61000-4-8 八、脉冲磁场抗扰度试验【IEC61000-4-9 九、电压跌落、短时中断和渐变抗扰度试验【IEC61000-4-11
十、谐波电流、电压波动和闪烁系统【IEC61000-3-2,IEC61000-3-3
十一、衰减震荡&振铃波抗扰度试验【IEC61000-4-12
十二、汽车电子沿电源线电瞬态传导抗扰度试验【ISO7637-2,GB/T21437
十三、电磁兼容屏蔽室建设方案【EN50147-1, GB12190
十四、传导发射测试系统【CISPR22十五、辐射发射测试系统【CISPR22
十六、喀呖声干扰测试系统【CISPR22

 

标签: generator
打赏

免责声明:
本站部份内容系网友自发上传与转载,不代表本网赞同其观点;
如涉及内容、版权等问题,请在30日内联系,我们将在第一时间删除内容!

购物指南

支付方式

商家合作

关于我们

微信扫一扫

(c)2008-2018 DESTOON B2B SYSTEM All Rights Reserved
免责声明:以上信息由相关企业或个人自行免费发布,其真实性、准确性及合法性未证实。请谨慎采用,风险自负。本网对此不承担任何法律责任。

在线咨询

在线咨询:

QQ交流群

微信公众号