Ring wave generator (from site:sz3ctest)

来源:网络  作者:网络转载   2019-09-29 阅读:434
As the power supply and control switch (or triggered by lightning) generated by transient phenomena, in the power lines, control lines and signal line generated ring-wave interference, and to this end in the domestic, commercial and industrial electrical and electronic equipment, anti - Scrambling degrees to establish a common performance evaluation criteria. SGZ-6012G Smart ringing wave simulator to meet GB/T17626.12 IEC61000-4-12 (2006 version) and ANSI C62.41 / 45 of the latest demand.
● Large LCD screen display, built-in computer control, human-computer dialogue, simple operation
● the main switch using the import of electronic switches, to ensure that the waveform stability, and comparability of strong, long life
● program-controlled high voltage power supply, voltage stability and high accuracy, voltage current monitoring
● positive or negative automatic switch test can be alternay positive and negative polarity switch
● trial software control without human operation
● surge into the phase angle of 0-360 ° is free to set up
● can establish a connection Oscillograph communications, direct observation of waveform (optional)
● computer communication interface, can be implemented remote control
Main technical parameters

Specification:

Open circuit voltage oscillation frequency(1/T)

100KHz±10%

Open-circuit output voltage  (PK1)

(250V~6000V)±10%

The forefront of the open circuit voltage waveform(T1) (10%~90%)

PK1(0.5μs±30%)

Open-circuit voltage decay rate:

40%<(PK2)/(PK1) < 110%

40%<(PK3)/(PK2)<80%

40%<(PK4)/(PK3)<80%

Short-circuit current wave of cutting-edge (T2) (10% ~ 90%)

P1≤0.9μs

Open circuit voltage (PK1) 6000V when the short-circuit current (P1)

12Ω时500A ±10%

30Ω时200A±10%

200Ω 30A±10%(Matching)

Adjacent pulse interval

1s~99s

Pulse frequency

1~9999 times

Output mode

Automatic switching or alternating positive and negative polarity

Output impedance

12Ω,30Ω

Phase into the way

Asynchronous or synchronous  (0º~360º)±10º

Sample coupling / decoupling network

Automatic matching lightning network

SGN-5010G(Single-phase 16A)

SGN-20G(Three-phase five-wire 16A)

SIZES(D×W×H)mm

560×475×245

交流咨询:   在线:
 欢迎交流电磁兼容EMC&高压测试(冲击电压、冲击电流)进入:了解更多其他配置方案及知识电磁兼容配置方案一、电磁兼容知识大汇总二、静电放电抗干扰试验系统【IEC61000-4-2 三、射频磁场辐射抗绕度试验【IEC61000-4-3 四、电快速瞬变脉冲群的抗干扰度试验【IEC61000-4-4 五、雷击浪涌抗干扰度试验【IEC61000-4-5 六、射频传导抗扰度试验【IEC61000-4-6 七、工频磁场抗扰度试验【IEC61000-4-8 八、脉冲磁场抗扰度试验【IEC61000-4-9 九、电压跌落、短时中断和渐变抗扰度试验【IEC61000-4-11
十、谐波电流、电压波动和闪烁系统【IEC61000-3-2,IEC61000-3-3
十一、衰减震荡&振铃波抗扰度试验【IEC61000-4-12
十二、汽车电子沿电源线电瞬态传导抗扰度试验【ISO7637-2,GB/T21437
十三、电磁兼容屏蔽室建设方案【EN50147-1, GB12190
十四、传导发射测试系统【CISPR22十五、辐射发射测试系统【CISPR22
十六、喀呖声干扰测试系统【CISPR22

 

标签: wave
打赏

免责声明:
本站部份内容系网友自发上传与转载,不代表本网赞同其观点;
如涉及内容、版权等问题,请在30日内联系,我们将在第一时间删除内容!

购物指南

支付方式

商家合作

关于我们

微信扫一扫

(c)2008-2018 DESTOON B2B SYSTEM All Rights Reserved
免责声明:以上信息由相关企业或个人自行免费发布,其真实性、准确性及合法性未证实。请谨慎采用,风险自负。本网对此不承担任何法律责任。

在线咨询

在线咨询:

QQ交流群

微信公众号